| Mechanical Characteristics |
| |
|
|
|
|
|
| Length |
(mm) |
660 |
|
|
|
| Width |
(mm) |
550 |
|
|
|
| Height |
(mm) |
36 |
|
|
|
| Weight |
(Kg) |
4 |
|
|
|
| Junction Box |
1 x Tyco junction Box with 1 diodes |
|
|
|
| Cables |
|
OPTIONAL: Solar Cable(1000 x 4mm²) Assembled with Tyco Connectors |
|
| Front Substrate |
Low Iron tempered White Glass 3.2 mm Thickness |
|
| Cells |
|
36 Polycrystalline cells (156 x 52 mm) or Mono (125x62.5mm) |
|
| Encapsulation Material |
EVA - Ethylene Vinyl Acetate |
|
|
|
| Back Substrate |
Composite Sheet Tedlar or APA |
|
|
|
| Frame |
|
36 mm Aluminum profile - Natural or Black Anodized |
|
|
| |
|
|
|
|
|
| Electrical Characteristics |
| |
| |
|
|
|
|
| Power Class |
Wp |
50 |
45 |
40 |
| Power Tolerance |
|
+5/- 2 W |
+5/- 2 W |
+5/- 2 W |
| Min Power |
Wp |
48 |
43 |
38 |
| Voltage at Max Power (Vmp) |
V |
17.4 |
17.3 |
17.1 |
| Current at Max Power (Imp) |
A |
2.66 |
2.50 |
2.34 |
| Open circuit Voltage (Voc) |
V |
21.8 |
21.7 |
21.5 |
| Short Circuit Current (Isc) |
A |
2.81 |
2.67 |
2.53 |
| Maximum System Voltage |
V |
1000 |
1000 |
1000 |
|
| |
|
|
|
|
|
| Voltage temperature correction factor (Open Circuit) |
-0.35%/K |
|
|
| Current Temperature correction factor (Short Circuit) |
0.05%/K |
|
|
| Power Temperature correction Factor |
-0.44 %/K |
|
|
| NOCT |
|
|
45°C |
|
|
| (STC) Standard testing conditions : |
1000 W/m², AM 1.5, 25°C |
| |
|
|
|
|
|
| Use Conditions |
| |
|
|
|
|
|
| Temperature Range |
-40 °C to + 85°C |
|
|
|
| Hail Test |
|
Limited to a diameter of 28mm at an impact speed of 86 km/h |
|
| Test Load |
|
Certified internally up to 5400 Pa according to IEC 61215 Ed. 2 |
|
| |
|
|
|
|
|
| Certification |
| |
|
|
|
|
|
| IEC 61215:2005 Ed. 2 |
Certification in progress |
|
|
|
| EN6170 Class 1 & Class 2 |
Certification in progress |
|
|
|
| |
|
|
|
|
|
| Warranty |
| |
|
|
|
|
|
| Product |
|
2 years |
|
|
|
| Power |
|
Terrestrial: 25 years 80% yield |
|
|
|
| |
|
Marine: 10 years / 90% yield |
|
|
|
| |
|
 |
|
Version 05/2009. Can be modified without notice. Average Electrical characteristics for Power class. Power tolerance related to power class before <<LID>> /Pictures and Drawings Are not contractual |
|
 |
|